Endograft repair of spontaneous infrarenal abdominal aortic dissection

2005

A 71-year-old man with a history of hypertension and a recent myocardial infarction experienced a sudden periumbilical and back pain. Abdominal tenderness was found at physical examination, with no changes in electrocardiogram and serial enzyme determinations. Computed tomographic angiography (CTA) showed a normal thoracic aorta, an infrarenal aortic dissection extending into the left common iliac artery and a contralateral iliac occlusive disease (A, Cover). Although antihypertensive therapy was administered, the patient had persistent pain; subsequently, he underwent endovascular repair with a bifurcated stent graft (Talent, Medtronic Ave, Santa Rosa, Calif) introduced via the left femora…

Malemedicine.medical_specialtymedicine.medical_treatmentDissection (medical)Settore MED/22 - Chirurgia VascolareAneurysm Dissectingmedicine.arteryMedicineThoracic aortaHumanscardiovascular diseasesAgedAortic dissectionbusiness.industryVascular diseaseAbdominal aortaStentendovascular repair aortic dissectionLeft Common Iliac Arterymedicine.diseaseAortic DissectionIntroducer sheathSurgeryRadiologybusinessCardiology and Cardiovascular MedicineVascular Surgical ProceduresHumanAortic Aneurysm AbdominalJournal of Vascular Surgery
researchProduct

Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

2019

Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…

Pigtailmedicine.medical_specialtyPercutaneouscannulation610 Medicine & healthSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationRetrospective Studiemedicine.arterygatemedicineStentFluoroscopyHumansEVARREVARRenal arteryRetrospective StudiesAortamedicine.diagnostic_testbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Proceduresmedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisCatheterBlood Vessel ProsthesiTreatment Outcomecontralateral limbIntroducer sheathStentsCardiology and Cardiovascular MedicinebusinessHumanAortic Aneurysm Abdominal